STG700 SmartLine Gauge Pressure

· Accuracies up to 0.065% of span.

· Stability up to 0.020% of URL per year for 10 years.

· Automatic temperature compensation.

· Rangeability up to 100:1.

· Response times as fast as 100ms .

· Easy to use and intuitive display capabilities.

· Intuitive External Zero, Span and configuration capability.

· Comprehensive on-board diagnostic capabilities.

· Integral Dual Seal design for safety based on ANSI/NFPA 70-202 and ANSI/ISA 12.27.0.

· Full compliance to SIL 2/3 requirements.

· Modular design characteristics.

· Available with additional 4-year warranty.

Span & Range Limits:

 

Model

URL

psi (bar)

LRL

psi (bar)

Min Span psi (bar)

STG735/STG73S

50 (3.5)

-14.7 (-1.0)

0.5 (0.035)

STG745/STG74S

500 (35)

-14.7 (-1.0)

5 (0.35)

STG775/STG77S

3000 (210)

-14.7 (-1.0)

30 (2.1)

STG78S

6000 (420)

-14.7 (-1.0)

60 (4.2)

STG79S

10000 (690)

-14.7 (-1.0)

100 (6.9)

Standard LCD Display Features

· Modular (may be added or removed in the field).

· Supports HART protocol variant.

· 0, 90,180, & 270 degree position adjustments.

· Four configurable screens.

· Standard and custom measurement units available.

· Display calculated flow (square root) value in addition to analog output signal.

· 2 Lines 6 digits PV (9.95H x 4.20W mm) 8 Characters.

· Write protect Indication.

· Built-in Basic Device Configuration through Internal or External Buttons – Range/Engineering Unit/Loop Test/Loop Calibration/Zero /Span Setting.

· Multiple language capabilities (EN, RU).

Reference Accuracy: (conformance to +/-3 Sigma)

 

Zero and span may be set anywhere within the listed (URL/LRL) range limits

Accuracy, Span and Temperature Effect: (Conformance to +/-3 Sigma)

 

Total Performance (% of Span):

 

Total Performance Examples (for comparison): (standard accuracy, 5:1 Turndown, +/-50oF (28oC) shift)

STG735 @ 10 psi: 0.128% of span  STG73S @ 10 psi: 0.187% of span

STG745 @ 100 psi: 0.154% of span  STG74S @ 100 psi: 0.210% of span

STG775 @ 600 psi: 0.154 % of span  STG77S @ 600 psi: 0.234% of span

STG78S @ 1200 psi: 0.455% of span  STG79S @ 2000 psi: 1.052% of span

Typical Calibration Frequency:

Calibration verification is recommended every two (2) years

Notes:

1.Terminal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0 .006% of span.

2.For zero based spans and reference conditions of: 25oC (77oF) for LRV > = 0 psia, 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.

Related Products
Welcome to tell us your needs
Submit
Send Inquiry
Submit

We provide bespoke industry solutions for diverse sectors.

Contact Us

Wechat/WhatsApp:

+86-137 5141 1282(Dawei.Cai)

Email:

dawei.cai@paires-tech.com

Address:

Room 430, Building 1, No. 6, Headquarters 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province.

Copyright © Dongguan Paires Equipment Co., Ltd., Technical Support: Shangxian Sitexml